For a prestressed concrete bridge beam, a minimum clear spacing of the cable of group of cables should be
Solution Breakdown:
The grouping of cable is permissible but not more than two cables should touch each other in vertical plan and minimum spacing in vertical planes between such grouped cable should be 50mm
Question 42Hard
The cable for a prestressed concrete simply supported beam subject to a uniformly distributed load over the entire span should ideally be
Solution Breakdown:
It should be ideal if it has parabolic profile with zero eccentricity at the ends and maximum eccentricity at the centre of the span.Due to this dead load is carried free of cost
Question 43Hard
At the time of initial tensioning, the maximum tensile stress in tendon immediately behind the anchorage shall not exceed
Solution Breakdown:
As per IS code 1343,the maximum tensile stress in tendon immediately behind the anchorage shall not exceed 80% of the ultimate tensile strength of wire or bar or strand
Question 44Medium
In the design of two way slab restrained at all esges, torsional reinforcement required is
Solution Breakdown:
As per IS code 456:1978 the torsional reinforcement required is 0.75 times that of the area of steel provided at the mid span in the same direction
Question 45Medium
A reinforced concrete slab is 75mm thick. The maximum size of reinforcement bar that can be used is
Solution Breakdown:
The diameter of reinforcing bar shall not exceed the one right of the total thickness of slab i.e 75/8=9.375, hence use 8mm dia bar
Question 46Hard
The final deflection due to all load including the effect of temperature, creep and shrinkage measured from as cast level of supports of floors,roofs and all other horizontal members should not exceed
Solution Breakdown:
As per IS code 456:1978,the final deflection due to all loads including the effects of temperature,creep and shrinkage for all the horizontal members shouldnot exceed span/250
Question 47Medium
The reduction coefficient of a reinforced concrete column with an effective length of 4.8m and size 250 mm x 300 mm is
Solution Breakdown:
From formula, reduction coefficient is equal to Cr,
Question 48Hard
A 200mm thick brick masonry wall made of modular bricks carries an axial load of 30KN/m from wall above and an eccentric load of 20KN/m from RCC floor acting at a distance of 47.5mm from centre line of the wall. The resultant eccentricity ratio is
Solution Breakdown:
Thickness of wall=200mm ,e1=47.5mm
Question 49Hard
A 200mm thick wall made of modular bricks is 5m long between cross walls and 3.8m clear height between RCC slabs at top and bottom. The slenderness ratio of the wall is
Solution Breakdown:
Slenderness ratio of wall = Height/thickness=(3.8*1000)/200=19
Question 50Medium
In a tilted aerial photograph, if the swing is 230°, then the rotation angle is equal to
Solution Breakdown:
While a specific detailed explanation is not available for this query, reviewing the core principles of Civil Engineering will help clarify the concept. This principle is vital for GATE, SSC JE, State Engineering Services, and PSU recruitment exams. Consistent practice is the key to mastering these patterns.